US Veterans Health Administration FHIR Map Set Implementation Guide
1.3.1 - 250401
Publication Build: This will be filled in by the publication tooling
Official URL: http://va.gov/fhir/StructureDefinition/ImplantableDeviceTransmitter | Version: 1.3.1 | |||
Active as of 2025-03-31 | Computable Name: ImplantableDeviceTransmitter |
This StructureDefinition contains the maps for VistA file GENERATOR IMPLANT (698) to us-core-implantable-device.
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() |
0..* | USCoreImplantableDeviceProfile(5.0.1) | Item used in healthcare This profile also complies with the profiles US Core Implantable Device Profile (6.1.0) and US Core Implantable Device Profile (7.0.0) dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated dom-5: If a resource is contained in another resource, it SHALL NOT have a security label dom-6: A resource should have narrative for robust management | |
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
![]() ![]() ![]() |
0..* | Identifier | Instance identifier ele-1: All FHIR elements must have a @value or children | |
![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() ![]() |
SΣ | 0..1 | uri | The namespace for the identifier value ele-1: All FHIR elements must have a @value or children Required Pattern: http://va.gov/identifiers/$Sta3n/698 |
![]() ![]() ![]() ![]() |
SΣ | 0..1 | string | The value that is unique ele-1: All FHIR elements must have a @value or children Example General: 123456 |
![]() ![]() ![]() |
SΣ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Mandatory fixed portion of UDI ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() ![]() |
SΣ | 0..1 | string | UDI Human Readable Barcode String ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
?!SΣC | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. ele-1: All FHIR elements must have a @value or children idt-28-1356: If (698-96) is is NULL then fixed value #active idt-28-1357: If (698-96) is is not NULL then fixed value #inactive |
![]() ![]() ![]() |
S | 0..1 | string | The distinct identification string ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
S | 0..1 | string | Name of device manufacturer ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
S | 0..1 | dateTime | Date when the device was made ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
S | 0..1 | dateTime | Date and time of expiry of this device (if applicable) ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
S | 0..1 | string | Lot number of manufacture ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
S | 0..1 | string | Serial number assigned by the manufacturer ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
S | 0..1 | string | The model number for the device ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | The kind or type of device Binding: deviceTypePacemaker FHIR (required): see mapping VF_deviceTypePacemaker ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
S | 1..1 | Reference(Patient) | Patient to whom Device is affixed ele-1: All FHIR elements must have a @value or children |
![]() |
Path | Conformance | ValueSet | URI |
Device.identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | |
Device.type | required | DeviceTypePacemakerhttp://va.gov/fhir/ValueSet/deviceTypePacemaker from this IG |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Device | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
idt-28-1356 | warning | Device.status | If (698-96) is is NULL then fixed value #active : true | |
idt-28-1357 | warning | Device.status | If (698-96) is is not NULL then fixed value #inactive : true |
This structure is derived from USCoreImplantableDeviceProfile
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() |
0..* | USCoreImplantableDeviceProfile(5.0.1) | Item used in healthcare This profile also complies with the profiles US Core Implantable Device Profile (6.1.0) and US Core Implantable Device Profile (7.0.0) | |
![]() ![]() ![]() |
||||
![]() ![]() ![]() ![]() |
S | 0..1 | uri | The namespace for the identifier value Required Pattern: http://va.gov/identifiers/$Sta3n/698 |
![]() ![]() ![]() ![]() |
S | 0..1 | string | The value that is unique |
![]() ![]() ![]() |
||||
![]() ![]() ![]() ![]() |
1..1 | string | Mandatory fixed portion of UDI | |
![]() ![]() ![]() ![]() |
0..1 | string | UDI Human Readable Barcode String | |
![]() ![]() ![]() |
SC | 0..1 | code | active | inactive | entered-in-error | unknown idt-28-1356: If (698-96) is is NULL then fixed value #active idt-28-1357: If (698-96) is is not NULL then fixed value #inactive |
![]() ![]() ![]() |
0..1 | string | The distinct identification string | |
![]() ![]() ![]() |
S | 0..1 | string | Name of device manufacturer |
![]() ![]() ![]() |
0..1 | dateTime | Date when the device was made | |
![]() ![]() ![]() |
0..1 | dateTime | Date and time of expiry of this device (if applicable) | |
![]() ![]() ![]() |
0..1 | string | Lot number of manufacture | |
![]() ![]() ![]() |
0..1 | string | Serial number assigned by the manufacturer | |
![]() ![]() ![]() |
S | 0..1 | string | The model number for the device |
![]() ![]() ![]() |
1..1 | CodeableConcept | The kind or type of device Binding: deviceTypePacemaker FHIR (required): see mapping VF_deviceTypePacemaker | |
![]() ![]() ![]() |
1..1 | Reference(Patient) | Patient to whom Device is affixed | |
![]() |
Path | Conformance | ValueSet | URI |
Device.type | required | DeviceTypePacemakerhttp://va.gov/fhir/ValueSet/deviceTypePacemaker from this IG |
Id | Grade | Path(s) | Details | Requirements |
idt-28-1356 | warning | Device.status | If (698-96) is is NULL then fixed value #active : true | |
idt-28-1357 | warning | Device.status | If (698-96) is is not NULL then fixed value #inactive : true |
Name | Flags | Card. | Type | Description & Constraints![]() | ||||
---|---|---|---|---|---|---|---|---|
![]() ![]() |
0..* | USCoreImplantableDeviceProfile(5.0.1) | Item used in healthcare This profile also complies with the profiles US Core Implantable Device Profile (6.1.0) and US Core Implantable Device Profile (7.0.0) | |||||
![]() ![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
![]() ![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() ![]() |
0..* | Identifier | Instance identifier | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
![]() ![]() ![]() ![]() |
SΣ | 0..1 | uri | The namespace for the identifier value Required Pattern: http://va.gov/identifiers/$Sta3n/698 | ||||
![]() ![]() ![]() ![]() |
SΣ | 0..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() ![]() |
0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |||||
![]() ![]() ![]() |
SΣ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Mandatory fixed portion of UDI | ||||
![]() ![]() ![]() ![]() |
0..1 | uri | UDI Issuing Organization | |||||
![]() ![]() ![]() ![]() |
0..1 | uri | Regional UDI authority | |||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
![]() ![]() ![]() ![]() |
SΣ | 0..1 | string | UDI Human Readable Barcode String | ||||
![]() ![]() ![]() ![]() |
0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
![]() ![]() ![]() |
?!SΣC | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. idt-28-1356: If (698-96) is is NULL then fixed value #active idt-28-1357: If (698-96) is is not NULL then fixed value #inactive | ||||
![]() ![]() ![]() |
0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
![]() ![]() ![]() |
S | 0..1 | string | The distinct identification string | ||||
![]() ![]() ![]() |
S | 0..1 | string | Name of device manufacturer | ||||
![]() ![]() ![]() |
S | 0..1 | dateTime | Date when the device was made | ||||
![]() ![]() ![]() |
S | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | ||||
![]() ![]() ![]() |
S | 0..1 | string | Lot number of manufacture | ||||
![]() ![]() ![]() |
S | 0..1 | string | Serial number assigned by the manufacturer | ||||
![]() ![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |||||
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
![]() ![]() ![]() |
S | 0..1 | string | The model number for the device | ||||
![]() ![]() ![]() |
0..1 | string | The part number of the device | |||||
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | The kind or type of device Binding: deviceTypePacemaker FHIR (required): see mapping VF_deviceTypePacemaker | ||||
![]() ![]() ![]() |
0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
![]() ![]() ![]() ![]() |
0..1 | string | The version of the standard that is used to operate and communicate | |||||
![]() ![]() ![]() |
0..* | BackboneElement | The actual design of the device or software version running on the device | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
0..1 | CodeableConcept | The type of the device version | |||||
![]() ![]() ![]() ![]() |
0..1 | Identifier | A single component of the device version | |||||
![]() ![]() ![]() ![]() |
1..1 | string | The version text | |||||
![]() ![]() ![]() |
0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
![]() ![]() ![]() ![]() |
0..* | Quantity | Property value as a quantity | |||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
![]() ![]() ![]() |
S | 1..1 | Reference(Patient) | Patient to whom Device is affixed | ||||
![]() ![]() ![]() |
0..1 | Reference(Organization) | Organization responsible for device | |||||
![]() ![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | |||||
![]() ![]() ![]() |
0..1 | Reference(Location) | Where the device is found | |||||
![]() ![]() ![]() |
0..1 | uri | Network address to contact device | |||||
![]() ![]() ![]() |
0..* | Annotation | Device notes and comments | |||||
![]() ![]() ![]() |
Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
![]() ![]() ![]() |
0..1 | Reference(Device) | The parent device | |||||
![]() |
Path | Conformance | ValueSet | URI | |||
Device.language | preferred | CommonLanguageshttp://hl7.org/fhir/ValueSet/languages from the FHIR Standard
| ||||
Device.identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | ||||
Device.identifier.type | extensible | Identifier Type Codeshttp://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | ||||
Device.udiCarrier.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1 from the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | ||||
Device.statusReason | extensible | FHIRDeviceStatusReasonhttp://hl7.org/fhir/ValueSet/device-status-reason from the FHIR Standard | ||||
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | ||||
Device.type | required | DeviceTypePacemakerhttp://va.gov/fhir/ValueSet/deviceTypePacemaker from this IG |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Device | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
idt-28-1356 | warning | Device.status | If (698-96) is is NULL then fixed value #active : true | |
idt-28-1357 | warning | Device.status | If (698-96) is is not NULL then fixed value #inactive : true |
This structure is derived from USCoreImplantableDeviceProfile
Key Elements View
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() |
0..* | USCoreImplantableDeviceProfile(5.0.1) | Item used in healthcare This profile also complies with the profiles US Core Implantable Device Profile (6.1.0) and US Core Implantable Device Profile (7.0.0) dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated dom-5: If a resource is contained in another resource, it SHALL NOT have a security label dom-6: A resource should have narrative for robust management | |
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
![]() ![]() ![]() |
0..* | Identifier | Instance identifier ele-1: All FHIR elements must have a @value or children | |
![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() ![]() |
SΣ | 0..1 | uri | The namespace for the identifier value ele-1: All FHIR elements must have a @value or children Required Pattern: http://va.gov/identifiers/$Sta3n/698 |
![]() ![]() ![]() ![]() |
SΣ | 0..1 | string | The value that is unique ele-1: All FHIR elements must have a @value or children Example General: 123456 |
![]() ![]() ![]() |
SΣ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Mandatory fixed portion of UDI ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() ![]() |
SΣ | 0..1 | string | UDI Human Readable Barcode String ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
?!SΣC | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. ele-1: All FHIR elements must have a @value or children idt-28-1356: If (698-96) is is NULL then fixed value #active idt-28-1357: If (698-96) is is not NULL then fixed value #inactive |
![]() ![]() ![]() |
S | 0..1 | string | The distinct identification string ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
S | 0..1 | string | Name of device manufacturer ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
S | 0..1 | dateTime | Date when the device was made ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
S | 0..1 | dateTime | Date and time of expiry of this device (if applicable) ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
S | 0..1 | string | Lot number of manufacture ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
S | 0..1 | string | Serial number assigned by the manufacturer ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
S | 0..1 | string | The model number for the device ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | The kind or type of device Binding: deviceTypePacemaker FHIR (required): see mapping VF_deviceTypePacemaker ele-1: All FHIR elements must have a @value or children |
![]() ![]() ![]() |
S | 1..1 | Reference(Patient) | Patient to whom Device is affixed ele-1: All FHIR elements must have a @value or children |
![]() |
Path | Conformance | ValueSet | URI |
Device.identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | |
Device.type | required | DeviceTypePacemakerhttp://va.gov/fhir/ValueSet/deviceTypePacemaker from this IG |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Device | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
idt-28-1356 | warning | Device.status | If (698-96) is is NULL then fixed value #active : true | |
idt-28-1357 | warning | Device.status | If (698-96) is is not NULL then fixed value #inactive : true |
Differential View
This structure is derived from USCoreImplantableDeviceProfile
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() |
0..* | USCoreImplantableDeviceProfile(5.0.1) | Item used in healthcare This profile also complies with the profiles US Core Implantable Device Profile (6.1.0) and US Core Implantable Device Profile (7.0.0) | |
![]() ![]() ![]() |
||||
![]() ![]() ![]() ![]() |
S | 0..1 | uri | The namespace for the identifier value Required Pattern: http://va.gov/identifiers/$Sta3n/698 |
![]() ![]() ![]() ![]() |
S | 0..1 | string | The value that is unique |
![]() ![]() ![]() |
||||
![]() ![]() ![]() ![]() |
1..1 | string | Mandatory fixed portion of UDI | |
![]() ![]() ![]() ![]() |
0..1 | string | UDI Human Readable Barcode String | |
![]() ![]() ![]() |
SC | 0..1 | code | active | inactive | entered-in-error | unknown idt-28-1356: If (698-96) is is NULL then fixed value #active idt-28-1357: If (698-96) is is not NULL then fixed value #inactive |
![]() ![]() ![]() |
0..1 | string | The distinct identification string | |
![]() ![]() ![]() |
S | 0..1 | string | Name of device manufacturer |
![]() ![]() ![]() |
0..1 | dateTime | Date when the device was made | |
![]() ![]() ![]() |
0..1 | dateTime | Date and time of expiry of this device (if applicable) | |
![]() ![]() ![]() |
0..1 | string | Lot number of manufacture | |
![]() ![]() ![]() |
0..1 | string | Serial number assigned by the manufacturer | |
![]() ![]() ![]() |
S | 0..1 | string | The model number for the device |
![]() ![]() ![]() |
1..1 | CodeableConcept | The kind or type of device Binding: deviceTypePacemaker FHIR (required): see mapping VF_deviceTypePacemaker | |
![]() ![]() ![]() |
1..1 | Reference(Patient) | Patient to whom Device is affixed | |
![]() |
Path | Conformance | ValueSet | URI |
Device.type | required | DeviceTypePacemakerhttp://va.gov/fhir/ValueSet/deviceTypePacemaker from this IG |
Id | Grade | Path(s) | Details | Requirements |
idt-28-1356 | warning | Device.status | If (698-96) is is NULL then fixed value #active : true | |
idt-28-1357 | warning | Device.status | If (698-96) is is not NULL then fixed value #inactive : true |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints![]() | ||||
---|---|---|---|---|---|---|---|---|
![]() ![]() |
0..* | USCoreImplantableDeviceProfile(5.0.1) | Item used in healthcare This profile also complies with the profiles US Core Implantable Device Profile (6.1.0) and US Core Implantable Device Profile (7.0.0) | |||||
![]() ![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
![]() ![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() ![]() |
0..* | Identifier | Instance identifier | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
![]() ![]() ![]() ![]() |
SΣ | 0..1 | uri | The namespace for the identifier value Required Pattern: http://va.gov/identifiers/$Sta3n/698 | ||||
![]() ![]() ![]() ![]() |
SΣ | 0..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() ![]() |
0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |||||
![]() ![]() ![]() |
SΣ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | string | Mandatory fixed portion of UDI | ||||
![]() ![]() ![]() ![]() |
0..1 | uri | UDI Issuing Organization | |||||
![]() ![]() ![]() ![]() |
0..1 | uri | Regional UDI authority | |||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
![]() ![]() ![]() ![]() |
SΣ | 0..1 | string | UDI Human Readable Barcode String | ||||
![]() ![]() ![]() ![]() |
0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
![]() ![]() ![]() |
?!SΣC | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. idt-28-1356: If (698-96) is is NULL then fixed value #active idt-28-1357: If (698-96) is is not NULL then fixed value #inactive | ||||
![]() ![]() ![]() |
0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
![]() ![]() ![]() |
S | 0..1 | string | The distinct identification string | ||||
![]() ![]() ![]() |
S | 0..1 | string | Name of device manufacturer | ||||
![]() ![]() ![]() |
S | 0..1 | dateTime | Date when the device was made | ||||
![]() ![]() ![]() |
S | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | ||||
![]() ![]() ![]() |
S | 0..1 | string | Lot number of manufacture | ||||
![]() ![]() ![]() |
S | 0..1 | string | Serial number assigned by the manufacturer | ||||
![]() ![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |||||
![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
![]() ![]() ![]() |
S | 0..1 | string | The model number for the device | ||||
![]() ![]() ![]() |
0..1 | string | The part number of the device | |||||
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | The kind or type of device Binding: deviceTypePacemaker FHIR (required): see mapping VF_deviceTypePacemaker | ||||
![]() ![]() ![]() |
0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
![]() ![]() ![]() ![]() |
0..1 | string | The version of the standard that is used to operate and communicate | |||||
![]() ![]() ![]() |
0..* | BackboneElement | The actual design of the device or software version running on the device | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
0..1 | CodeableConcept | The type of the device version | |||||
![]() ![]() ![]() ![]() |
0..1 | Identifier | A single component of the device version | |||||
![]() ![]() ![]() ![]() |
1..1 | string | The version text | |||||
![]() ![]() ![]() |
0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
![]() ![]() ![]() ![]() |
0..* | Quantity | Property value as a quantity | |||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
![]() ![]() ![]() |
S | 1..1 | Reference(Patient) | Patient to whom Device is affixed | ||||
![]() ![]() ![]() |
0..1 | Reference(Organization) | Organization responsible for device | |||||
![]() ![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | |||||
![]() ![]() ![]() |
0..1 | Reference(Location) | Where the device is found | |||||
![]() ![]() ![]() |
0..1 | uri | Network address to contact device | |||||
![]() ![]() ![]() |
0..* | Annotation | Device notes and comments | |||||
![]() ![]() ![]() |
Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
![]() ![]() ![]() |
0..1 | Reference(Device) | The parent device | |||||
![]() |
Path | Conformance | ValueSet | URI | |||
Device.language | preferred | CommonLanguageshttp://hl7.org/fhir/ValueSet/languages from the FHIR Standard
| ||||
Device.identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | ||||
Device.identifier.type | extensible | Identifier Type Codeshttp://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | ||||
Device.udiCarrier.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1 from the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | ||||
Device.statusReason | extensible | FHIRDeviceStatusReasonhttp://hl7.org/fhir/ValueSet/device-status-reason from the FHIR Standard | ||||
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | ||||
Device.type | required | DeviceTypePacemakerhttp://va.gov/fhir/ValueSet/deviceTypePacemaker from this IG |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Device | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
idt-28-1356 | warning | Device.status | If (698-96) is is NULL then fixed value #active : true | |
idt-28-1357 | warning | Device.status | If (698-96) is is not NULL then fixed value #inactive : true |
This structure is derived from USCoreImplantableDeviceProfile
Other representations of profile: CSV, Excel, Schematron