This StructureDefinition contains the maps for VistA file GMRV VITAL MEASUREMENT (120.5) to us-core-blood-pressure.
See also the FHIR Shorthand.
Usages:
You can also check for usages in the FHIR IG Statistics
Description of Profiles, Differentials, Snapshots and how the different presentations work.
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
C | 0..* | USCoreBloodPressureProfile(5.0.1) | US Core Blood Pressure Profile This profile also complies with the profiles US Core Blood Pressure Profile (6.1.0) and US Core Blood Pressure Profile (7.0.0) Constraints: obs-6, obs-7, vs-2 |
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
S | 0..1 | (Complex) | A code representing the the type of device used for this observation. Should only be used if not implicit in the code found in `Observation.code` URL: http://hl7.org/fhir/StructureDefinition/observation-deviceCode |
![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/StructureDefinition/observation-deviceCode" | |
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension Binding: VitalsMeasurementDevice FHIR (required): see mapping VF_VitalsMeasurementDevice |
![]() ![]() ![]() |
S | 0..1 | (Complex) | The body position during the observation URL: http://hl7.org/fhir/StructureDefinition/observation-bodyPosition |
![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/StructureDefinition/observation-bodyPosition" | |
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension Binding: VitalsBodyPosition FHIR (required): see mapping VF_VitalsBodyPosition |
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() |
Σ | 0..* | Identifier | Business Identifier for observation |
![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
![]() ![]() ![]() |
SΣ | 0..1 | uri | The namespace for the identifier value Required Pattern: http://va.gov/identifiers/{sta3n}/120.5 |
![]() ![]() ![]() |
SΣ | 0..1 | string | The value that is unique Example General: 123456 |
![]() ![]() |
?!SΣC | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required) Constraints: vsbp-12-655, vsbp-12-656 |
![]() ![]() |
S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following |
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |
![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() ![]() ![]() |
SΣ | 1..* | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs |
![]() ![]() |
SΣ | 1..1 | CodeableConcept | Blood Pressure Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following |
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 85354-9 | |
![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |
![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() ![]() |
SΣ | 0..* | Coding | Code defined by a terminology system Binding: VitalsCodes FHIR (required): see mapping VF_VitalsCodes |
![]() ![]() |
SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about |
![]() ![]() |
SΣC | 1..1 | Often just a dateTime for Vital Signs Slice: Unordered, Open by type:$this Constraints: vs-1 | |
![]() ![]() ![]() |
dateTime S | |||
![]() ![]() ![]() |
Period | |||
![]() ![]() ![]() |
SΣC | 0..1 | dateTime S | Often just a dateTime for Vital Signs Constraints: vs-1 |
![]() ![]() |
SΣ | 0..1 | instant | Date/Time this version was made available |
![]() ![]() |
SΣ | 0..* | Reference(Organization) | Who is responsible for the observation |
![]() ![]() |
SΣC | 0..1 | Vital Signs Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |
![]() ![]() ![]() |
Quantity S | |||
![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() |
string | |||
![]() ![]() ![]() |
boolean | |||
![]() ![]() ![]() |
integer | |||
![]() ![]() ![]() |
Range | |||
![]() ![]() ![]() |
Ratio | |||
![]() ![]() ![]() |
SampledData | |||
![]() ![]() ![]() |
time | |||
![]() ![]() ![]() |
dateTime | |||
![]() ![]() ![]() |
Period | |||
![]() ![]() ![]() |
SΣC | 0..1 | Quantity S | Vital Signs Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-664 |
![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
![]() ![]() ![]() ![]() |
SΣ | 0..1 | code | Coded form of the unit |
![]() ![]() |
SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() |
S | 0..1 | CodeableConcept | Observed body part Binding: VitalsBodySite FHIR (required): see mapping VF_VitalsBodySite |
![]() ![]() |
S | 0..1 | CodeableConcept | How it was done Binding: VitalsMethod FHIR (required): see mapping VF_VitalsMethod |
![]() ![]() |
SΣC | 2..* | BackboneElement | Component observations Slice: Unordered, Open by pattern:code Constraints: vs-3 |
![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |
![]() ![]() ![]() ![]() ![]() |
Quantity S | |||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() ![]() ![]() |
string | |||
![]() ![]() ![]() ![]() ![]() |
boolean | |||
![]() ![]() ![]() ![]() ![]() |
integer | |||
![]() ![]() ![]() ![]() ![]() |
Range | |||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||
![]() ![]() ![]() ![]() ![]() |
time | |||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||
![]() ![]() ![]() ![]() ![]() |
Period | |||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() ![]() |
SΣC | 1..1 | BackboneElement | Systolic Blood Pressure Constraints: vs-3 |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣC | 1..1 | CodeableConcept | Systolic Blood Pressure Code Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Constraints: vsbp-12-666-3 Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 8480-6 | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-666 |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | string | Unit representation Constraints: vsbp-12-666-2 |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | code | Coded form of the unit Constraints: vsbp-12-666-1 Fixed Value: mm[Hg] |
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() ![]() |
SΣC | 1..1 | BackboneElement | Diastolic Blood Pressure Constraints: vs-3 |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣC | 1..1 | CodeableConcept | Diastolic Blood Pressure Code Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Constraints: vsbp-12-667-3 Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 8462-4 | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-667 |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | string | Unit representation Constraints: vsbp-12-667-2 |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | code | Coded form of the unit Constraints: vsbp-12-667-1 Fixed Value: mm[Hg] |
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() ![]() |
SΣC | 0..1 | BackboneElement | Component observations Constraints: vs-3 |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 8358-4 | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Blood pressure device cuff size | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Component Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |
![]() ![]() ![]() ![]() ![]() |
Quantity S | |||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() ![]() ![]() |
string | |||
![]() ![]() ![]() ![]() ![]() |
boolean | |||
![]() ![]() ![]() ![]() ![]() |
integer | |||
![]() ![]() ![]() ![]() ![]() |
Range | |||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||
![]() ![]() ![]() ![]() ![]() |
time | |||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||
![]() ![]() ![]() ![]() ![]() |
Period | |||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsCuffSize FHIR (required): see mapping VF_VitalsCuffSize |
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() ![]() |
SΣC | 0..1 | BackboneElement | Component observations Constraints: vs-3 |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 104158-1 | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Associated precondition - Reported | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Component Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |
![]() ![]() ![]() ![]() ![]() |
Quantity S | |||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() ![]() ![]() |
string | |||
![]() ![]() ![]() ![]() ![]() |
boolean | |||
![]() ![]() ![]() ![]() ![]() |
integer | |||
![]() ![]() ![]() ![]() ![]() |
Range | |||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||
![]() ![]() ![]() ![]() ![]() |
time | |||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||
![]() ![]() ![]() ![]() ![]() |
Period | |||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsPrecondition FHIR (required): see mapping VF_VitalsPrecondition |
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() ![]() |
SΣC | 0..1 | BackboneElement | Component observations Constraints: vs-3 |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 104158-1 | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Associated precondition - Reported | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Component Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |
![]() ![]() ![]() ![]() ![]() |
Quantity S | |||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() ![]() ![]() |
string | |||
![]() ![]() ![]() ![]() ![]() |
boolean | |||
![]() ![]() ![]() ![]() ![]() |
integer | |||
![]() ![]() ![]() ![]() ![]() |
Range | |||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||
![]() ![]() ![]() ![]() ![]() |
time | |||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||
![]() ![]() ![]() ![]() ![]() |
Period | |||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsQualifyingDevice FHIR (required): see mapping VF_VitalsQualifyingDevice |
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
Documentation for this format | ||||
| Path | Status | Usage | ValueSet | Version | Source |
| Observation.extension:observation-deviceCode.value[x] | Base | required | VitalsMeasurementDevice FHIR | 📦1.10.0 | This IG |
| Observation.extension:observation-bodyPosition.value[x] | Base | required | VitalsBodyPosition FHIR | 📦1.10.0 | This IG |
| Observation.identifier.use | Base | required | IdentifierUse | 📍4.0.1 | FHIR Std. |
| Observation.status | Base | required | ObservationStatus | 📍4.0.1 | FHIR Std. |
| Observation.category | Base | preferred | Observation Category Codes | 📦4.0.1 | FHIR Std. |
| Observation.category:VSCat | Base | preferred | Observation Category Codes | 📦4.0.1 | FHIR Std. |
| Observation.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.code.coding | Base | required | VitalsCodes FHIR | 📦1.10.0 | This IG |
| Observation.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.value[x]:valueQuantity | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.value[x]:valueQuantity.comparator | Base | required | QuantityComparator | 📍4.0.1 | FHIR Std. |
| Observation.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.bodySite | Base | required | VitalsBodySite FHIR | 📦1.10.0 | This IG |
| Observation.method | Base | required | VitalsMethod FHIR | 📦1.10.0 | This IG |
| Observation.component.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:systolic.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:systolic.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:systolic.value[x].comparator | Base | required | QuantityComparator | 📍4.0.1 | FHIR Std. |
| Observation.component:systolic.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:diastolic.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:diastolic.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:diastolic.value[x].comparator | Base | required | QuantityComparator | 📍4.0.1 | FHIR Std. |
| Observation.component:diastolic.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:va-cuff-size.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:va-cuff-size.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:va-cuff-size.value[x]:valueCodeableConcept | Base | required | VitalsCuffSize FHIR | 📦1.10.0 | This IG |
| Observation.component:va-cuff-size.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:va-pre-condition.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition.value[x]:valueCodeableConcept | Base | required | VitalsPrecondition FHIR | 📦1.10.0 | This IG |
| Observation.component:va-pre-condition.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition-device.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:va-pre-condition-device.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition-device.value[x]:valueCodeableConcept | Base | required | VitalsQualifyingDevice FHIR | 📦1.10.0 | This IG |
| Observation.component:va-pre-condition-device.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Observation | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
| obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present |
dataAbsentReason.empty() or value.empty()
|
| obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present |
value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty()
|
| vs-1 | error | Observation.effective[x], Observation.effective[x]:effectiveDateTime | if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day |
($this as dateTime).toString().length() >= 8
|
| vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. |
(component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists())
|
| vs-3 | error | Observation.component, Observation.component:systolic, Observation.component:diastolic, Observation.component:va-cuff-size, Observation.component:va-pre-condition, Observation.component:va-pre-condition-device | If there is no a value a data absent reason must be present |
value.exists() or dataAbsentReason.exists()
|
| vsbp-12-655 | best practice | Observation.status | If (120.5-4) is null then fixed value #final |
true
|
| vsbp-12-656 | best practice | Observation.status | If (120.5-4) is not null then fixed value #entered-in-error |
true
|
| vsbp-12-664 | best practice | Observation.value[x]:valueQuantity.value | If VUID not = 4500634 then source value from (120.5-1.2) |
true
|
| vsbp-12-666 | best practice | Observation.component:systolic.value[x].value | If VUID = 4500634 then transform (120.5-1.2) using Split_rate_value.Systolic() |
true
|
| vsbp-12-667 | best practice | Observation.component:diastolic.value[x].value | If VUID = 4500634 then transform (120.5-1.2) using Split_rate_value.Diastolic() |
true
|
| vsbp-12-667-1 | best practice | Observation.component:diastolic.value[x].code | If VUID = 4500634 then fixed value #mm[Hg] |
true
|
| vsbp-12-666-1 | best practice | Observation.component:systolic.value[x].code | If VUID = 4500634 then fixed value #mm[Hg] |
true
|
| vsbp-12-666-2 | best practice | Observation.component:systolic.value[x].unit | If VUID = 4500634 then fixed value mm[Hg] |
true
|
| vsbp-12-667-2 | best practice | Observation.component:diastolic.value[x].unit | If VUID = 4500634 then fixed value mm[Hg] |
true
|
| vsbp-12-667-3 | best practice | Observation.component:diastolic.code | If VUID = 4500634 then fixed value http://loinc.org#8462-4 |
true
|
| vsbp-12-666-3 | best practice | Observation.component:systolic.code | If VUID = 4500634 then fixed value http://loinc.org#8480-6 |
true
|
This structure is derived from USCoreBloodPressureProfile
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | USCoreBloodPressureProfile(5.0.1) | US Core Blood Pressure Profile This profile also complies with the profiles US Core Blood Pressure Profile (6.1.0) and US Core Blood Pressure Profile (7.0.0) | |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
S | 0..1 | (Complex) | A code representing the the type of device used for this observation. Should only be used if not implicit in the code found in `Observation.code` URL: http://hl7.org/fhir/StructureDefinition/observation-deviceCode |
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension Binding: VitalsMeasurementDevice FHIR (required): see mapping VF_VitalsMeasurementDevice |
![]() ![]() ![]() |
S | 0..1 | (Complex) | The body position during the observation URL: http://hl7.org/fhir/StructureDefinition/observation-bodyPosition |
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension Binding: VitalsBodyPosition FHIR (required): see mapping VF_VitalsBodyPosition |
![]() ![]() |
||||
![]() ![]() ![]() |
S | 0..1 | uri | The namespace for the identifier value Required Pattern: http://va.gov/identifiers/{sta3n}/120.5 |
![]() ![]() ![]() |
S | 0..1 | string | The value that is unique |
![]() ![]() |
C | 1..1 | code | registered | preliminary | final | amended + Constraints: vsbp-12-655, vsbp-12-656 |
![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() |
1..1 | CodeableConcept | Classification of type of observation Required Pattern: At least the following | |
![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | |
![]() ![]() |
||||
![]() ![]() ![]() |
S | 0..* | Coding | Code defined by a terminology system Binding: VitalsCodes FHIR (required): see mapping VF_VitalsCodes |
![]() ![]() |
1..1 | Reference(Patient) | Who and/or what the observation is about | |
![]() ![]() |
1..1 | dateTime, Period | Often just a dateTime for Vital Signs Slice: Unordered, Open by type:$this | |
![]() ![]() ![]() |
S | 0..1 | dateTime S | Often just a dateTime for Vital Signs |
![]() ![]() |
S | 0..1 | instant | Date/Time this version was made available |
![]() ![]() |
S | 0..* | Reference(Organization) | Who is responsible for the observation |
![]() ![]() |
0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Vital Signs Value Slice: Unordered, Open by type:$this | |
![]() ![]() ![]() |
0..1 | Quantity | Vital Signs Value | |
![]() ![]() ![]() ![]() |
SC | 0..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-664 |
![]() ![]() ![]() ![]() |
S | 0..1 | code | Coded form of the unit |
![]() ![]() |
S | 0..1 | CodeableConcept | Observed body part Binding: VitalsBodySite FHIR (required): see mapping VF_VitalsBodySite |
![]() ![]() |
S | 0..1 | CodeableConcept | How it was done Binding: VitalsMethod FHIR (required): see mapping VF_VitalsMethod |
![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() |
1..1 | BackboneElement | Systolic Blood Pressure | |
![]() ![]() ![]() ![]() |
C | 1..1 | CodeableConcept | Systolic Blood Pressure Code Constraints: vsbp-12-666-3 |
![]() ![]() ![]() ![]() |
||||
![]() ![]() ![]() ![]() ![]() |
C | 1..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-666 |
![]() ![]() ![]() ![]() ![]() |
C | 1..1 | string | Unit representation Constraints: vsbp-12-666-2 |
![]() ![]() ![]() ![]() ![]() |
C | 1..1 | code | Coded form of the unit Constraints: vsbp-12-666-1 |
![]() ![]() ![]() |
1..1 | BackboneElement | Diastolic Blood Pressure | |
![]() ![]() ![]() ![]() |
C | 1..1 | CodeableConcept | Diastolic Blood Pressure Code Constraints: vsbp-12-667-3 |
![]() ![]() ![]() ![]() |
||||
![]() ![]() ![]() ![]() ![]() |
C | 1..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-667 |
![]() ![]() ![]() ![]() ![]() |
C | 1..1 | string | Unit representation Constraints: vsbp-12-667-2 |
![]() ![]() ![]() ![]() ![]() |
C | 1..1 | code | Coded form of the unit Constraints: vsbp-12-667-1 |
![]() ![]() ![]() |
S | 0..1 | BackboneElement | Component observations |
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Type of component observation (code / type) Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 8358-4 | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Blood pressure device cuff size | |
![]() ![]() ![]() ![]() |
0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Vital Sign Component Value Slice: Unordered, Open by type:$this | |
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsCuffSize FHIR (required): see mapping VF_VitalsCuffSize |
![]() ![]() ![]() |
S | 0..1 | BackboneElement | Component observations |
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Type of component observation (code / type) Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 104158-1 | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Associated precondition - Reported | |
![]() ![]() ![]() ![]() |
0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Vital Sign Component Value Slice: Unordered, Open by type:$this | |
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsPrecondition FHIR (required): see mapping VF_VitalsPrecondition |
![]() ![]() ![]() |
S | 0..1 | BackboneElement | Component observations |
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Type of component observation (code / type) Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 104158-1 | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Associated precondition - Reported | |
![]() ![]() ![]() ![]() |
0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Vital Sign Component Value Slice: Unordered, Open by type:$this | |
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsQualifyingDevice FHIR (required): see mapping VF_VitalsQualifyingDevice |
Documentation for this format | ||||
| Path | Status | Usage | ValueSet | Version | Source |
| Observation.extension:observation-deviceCode.value[x] | Base | required | VitalsMeasurementDevice FHIR | 📦1.10.0 | This IG |
| Observation.extension:observation-bodyPosition.value[x] | Base | required | VitalsBodyPosition FHIR | 📦1.10.0 | This IG |
| Observation.code.coding | Base | required | VitalsCodes FHIR | 📦1.10.0 | This IG |
| Observation.bodySite | Base | required | VitalsBodySite FHIR | 📦1.10.0 | This IG |
| Observation.method | Base | required | VitalsMethod FHIR | 📦1.10.0 | This IG |
| Observation.component:va-cuff-size.value[x]:valueCodeableConcept | Base | required | VitalsCuffSize FHIR | 📦1.10.0 | This IG |
| Observation.component:va-pre-condition.value[x]:valueCodeableConcept | Base | required | VitalsPrecondition FHIR | 📦1.10.0 | This IG |
| Observation.component:va-pre-condition-device.value[x]:valueCodeableConcept | Base | required | VitalsQualifyingDevice FHIR | 📦1.10.0 | This IG |
| Id | Grade | Path(s) | Description | Expression |
| vsbp-12-655 | best practice | Observation.status | If (120.5-4) is null then fixed value #final |
true
|
| vsbp-12-656 | best practice | Observation.status | If (120.5-4) is not null then fixed value #entered-in-error |
true
|
| vsbp-12-664 | best practice | Observation.value[x]:valueQuantity.value | If VUID not = 4500634 then source value from (120.5-1.2) |
true
|
| vsbp-12-666 | best practice | Observation.component:systolic.value[x].value | If VUID = 4500634 then transform (120.5-1.2) using Split_rate_value.Systolic() |
true
|
| vsbp-12-667 | best practice | Observation.component:diastolic.value[x].value | If VUID = 4500634 then transform (120.5-1.2) using Split_rate_value.Diastolic() |
true
|
| vsbp-12-667-1 | best practice | Observation.component:diastolic.value[x].code | If VUID = 4500634 then fixed value #mm[Hg] |
true
|
| vsbp-12-666-1 | best practice | Observation.component:systolic.value[x].code | If VUID = 4500634 then fixed value #mm[Hg] |
true
|
| vsbp-12-666-2 | best practice | Observation.component:systolic.value[x].unit | If VUID = 4500634 then fixed value mm[Hg] |
true
|
| vsbp-12-667-2 | best practice | Observation.component:diastolic.value[x].unit | If VUID = 4500634 then fixed value mm[Hg] |
true
|
| vsbp-12-667-3 | best practice | Observation.component:diastolic.code | If VUID = 4500634 then fixed value http://loinc.org#8462-4 |
true
|
| vsbp-12-666-3 | best practice | Observation.component:systolic.code | If VUID = 4500634 then fixed value http://loinc.org#8480-6 |
true
|
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||
|---|---|---|---|---|---|---|---|---|
![]() |
C | 0..* | USCoreBloodPressureProfile(5.0.1) | US Core Blood Pressure Profile This profile also complies with the profiles US Core Blood Pressure Profile (6.1.0) and US Core Blood Pressure Profile (7.0.0) Constraints: obs-6, obs-7, vs-2 | ||||
![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
S | 0..1 | (Complex) | A code representing the the type of device used for this observation. Should only be used if not implicit in the code found in `Observation.code` URL: http://hl7.org/fhir/StructureDefinition/observation-deviceCode | ||||
![]() ![]() ![]() ![]() |
0..1 | id | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||||||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/StructureDefinition/observation-deviceCode" | |||||
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension Binding: VitalsMeasurementDevice FHIR (required): see mapping VF_VitalsMeasurementDevice | ||||
![]() ![]() ![]() |
S | 0..1 | (Complex) | The body position during the observation URL: http://hl7.org/fhir/StructureDefinition/observation-bodyPosition | ||||
![]() ![]() ![]() ![]() |
0..1 | id | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||||||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/StructureDefinition/observation-bodyPosition" | |||||
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension Binding: VitalsBodyPosition FHIR (required): see mapping VF_VitalsBodyPosition | ||||
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() |
Σ | 0..* | Identifier | Business Identifier for observation | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() |
Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
![]() ![]() ![]() |
SΣ | 0..1 | uri | The namespace for the identifier value Required Pattern: http://va.gov/identifiers/{sta3n}/120.5 | ||||
![]() ![]() ![]() |
SΣ | 0..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() |
Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
![]() ![]() |
Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
![]() ![]() |
?!SΣC | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required) Constraints: vsbp-12-655, vsbp-12-656 | ||||
![]() ![]() |
S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
SΣ | 1..* | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
SΣ | 1..1 | CodeableConcept | Blood Pressure Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 85354-9 | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |||||
![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
SΣ | 0..* | Coding | Code defined by a terminology system Binding: VitalsCodes FHIR (required): see mapping VF_VitalsCodes | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about | ||||
![]() ![]() |
Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
![]() ![]() |
Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
![]() ![]() |
SΣC | 1..1 | Often just a dateTime for Vital Signs Slice: Unordered, Open by type:$this Constraints: vs-1 | |||||
![]() ![]() ![]() |
dateTime S | |||||||
![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() |
SΣC | 0..1 | dateTime S | Often just a dateTime for Vital Signs Constraints: vs-1 | ||||
![]() ![]() |
SΣ | 0..1 | instant | Date/Time this version was made available | ||||
![]() ![]() |
SΣ | 0..* | Reference(Organization) | Who is responsible for the observation | ||||
![]() ![]() |
SΣC | 0..1 | Vital Signs Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |||||
![]() ![]() ![]() |
Quantity S | |||||||
![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() |
boolean | |||||||
![]() ![]() ![]() |
integer | |||||||
![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() |
Ratio | |||||||
![]() ![]() ![]() |
SampledData | |||||||
![]() ![]() ![]() |
time | |||||||
![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() |
SΣC | 0..1 | Quantity S | Vital Signs Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-664 | ||||
![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Unit representation | ||||
![]() ![]() ![]() ![]() |
ΣC | 0..1 | uri | System that defines coded unit form | ||||
![]() ![]() ![]() ![]() |
SΣ | 0..1 | code | Coded form of the unit | ||||
![]() ![]() |
SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() |
0..* | Annotation | Comments about the observation | |||||
![]() ![]() |
S | 0..1 | CodeableConcept | Observed body part Binding: VitalsBodySite FHIR (required): see mapping VF_VitalsBodySite | ||||
![]() ![]() |
S | 0..1 | CodeableConcept | How it was done Binding: VitalsMethod FHIR (required): see mapping VF_VitalsMethod | ||||
![]() ![]() |
0..1 | Reference(Specimen) | Specimen used for this observation | |||||
![]() ![]() |
0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||
![]() ![]() |
C | 0..* | BackboneElement | Provides guide for interpretation Constraints: obs-3 | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
![]() ![]() ![]() |
C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
![]() ![]() ![]() |
0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
![]() ![]() ![]() |
0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
![]() ![]() ![]() |
0..1 | Range | Applicable age range, if relevant | |||||
![]() ![]() ![]() |
0..1 | string | Text based reference range in an observation | |||||
![]() ![]() |
Σ | 0..* | Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Used when reporting vital signs panel components | ||||
![]() ![]() |
Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Related measurements the observation is made from | ||||
![]() ![]() |
SΣC | 2..* | BackboneElement | Component observations Slice: Unordered, Open by pattern:code Constraints: vs-3 | ||||
![]() ![]() ![]() |
Content/Rules for all slices | |||||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. | ||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |||||
![]() ![]() ![]() ![]() ![]() |
Quantity S | |||||||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() ![]() ![]() |
boolean | |||||||
![]() ![]() ![]() ![]() ![]() |
integer | |||||||
![]() ![]() ![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||||||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||||||
![]() ![]() ![]() ![]() ![]() |
time | |||||||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
![]() ![]() ![]() |
SΣC | 1..1 | BackboneElement | Systolic Blood Pressure Constraints: vs-3 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣC | 1..1 | CodeableConcept | Systolic Blood Pressure Code Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Constraints: vsbp-12-666-3 Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 8480-6 | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-666 | ||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | string | Unit representation Constraints: vsbp-12-666-2 | ||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | code | Coded form of the unit Constraints: vsbp-12-666-1 Fixed Value: mm[Hg] | ||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
![]() ![]() ![]() |
SΣC | 1..1 | BackboneElement | Diastolic Blood Pressure Constraints: vs-3 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣC | 1..1 | CodeableConcept | Diastolic Blood Pressure Code Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Constraints: vsbp-12-667-3 Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 8462-4 | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-667 | ||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | string | Unit representation Constraints: vsbp-12-667-2 | ||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | code | Coded form of the unit Constraints: vsbp-12-667-1 Fixed Value: mm[Hg] | ||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
![]() ![]() ![]() |
SΣC | 0..1 | BackboneElement | Component observations Constraints: vs-3 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 8358-4 | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Blood pressure device cuff size | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Component Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |||||
![]() ![]() ![]() ![]() ![]() |
Quantity S | |||||||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() ![]() ![]() |
boolean | |||||||
![]() ![]() ![]() ![]() ![]() |
integer | |||||||
![]() ![]() ![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||||||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||||||
![]() ![]() ![]() ![]() ![]() |
time | |||||||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsCuffSize FHIR (required): see mapping VF_VitalsCuffSize | ||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
![]() ![]() ![]() |
SΣC | 0..1 | BackboneElement | Component observations Constraints: vs-3 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 104158-1 | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Associated precondition - Reported | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Component Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |||||
![]() ![]() ![]() ![]() ![]() |
Quantity S | |||||||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() ![]() ![]() |
boolean | |||||||
![]() ![]() ![]() ![]() ![]() |
integer | |||||||
![]() ![]() ![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||||||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||||||
![]() ![]() ![]() ![]() ![]() |
time | |||||||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsPrecondition FHIR (required): see mapping VF_VitalsPrecondition | ||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
![]() ![]() ![]() |
SΣC | 0..1 | BackboneElement | Component observations Constraints: vs-3 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 104158-1 | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Associated precondition - Reported | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Component Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |||||
![]() ![]() ![]() ![]() ![]() |
Quantity S | |||||||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() ![]() ![]() |
boolean | |||||||
![]() ![]() ![]() ![]() ![]() |
integer | |||||||
![]() ![]() ![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||||||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||||||
![]() ![]() ![]() ![]() ![]() |
time | |||||||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsQualifyingDevice FHIR (required): see mapping VF_VitalsQualifyingDevice | ||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format | ||||||||
| Path | Status | Usage | ValueSet | Version | Source |
| Observation.language | Base | preferred | Common Languages | 📦4.0.1 | FHIR Std. |
| Observation.extension:observation-deviceCode.value[x] | Base | required | VitalsMeasurementDevice FHIR | 📦1.10.0 | This IG |
| Observation.extension:observation-bodyPosition.value[x] | Base | required | VitalsBodyPosition FHIR | 📦1.10.0 | This IG |
| Observation.identifier.use | Base | required | IdentifierUse | 📍4.0.1 | FHIR Std. |
| Observation.identifier.type | Base | extensible | IdentifierType | 📍4.0.1 | FHIR Std. |
| Observation.status | Base | required | ObservationStatus | 📍4.0.1 | FHIR Std. |
| Observation.category | Base | preferred | Observation Category Codes | 📦4.0.1 | FHIR Std. |
| Observation.category:VSCat | Base | preferred | Observation Category Codes | 📦4.0.1 | FHIR Std. |
| Observation.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.code.coding | Base | required | VitalsCodes FHIR | 📦1.10.0 | This IG |
| Observation.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.value[x]:valueQuantity | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.value[x]:valueQuantity.comparator | Base | required | QuantityComparator | 📍4.0.1 | FHIR Std. |
| Observation.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.interpretation | Base | extensible | Observation Interpretation Codes | 📦4.0.1 | FHIR Std. |
| Observation.bodySite | Base | required | VitalsBodySite FHIR | 📦1.10.0 | This IG |
| Observation.method | Base | required | VitalsMethod FHIR | 📦1.10.0 | This IG |
| Observation.referenceRange.type | Base | preferred | Observation Reference Range Meaning Codes | 📦4.0.1 | FHIR Std. |
| Observation.referenceRange.appliesTo | Base | example | Observation Reference Range Applies To Codes | 📦4.0.1 | FHIR Std. |
| Observation.component.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component.interpretation | Base | extensible | Observation Interpretation Codes | 📦4.0.1 | FHIR Std. |
| Observation.component:systolic.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:systolic.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:systolic.value[x].comparator | Base | required | QuantityComparator | 📍4.0.1 | FHIR Std. |
| Observation.component:systolic.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:systolic.interpretation | Base | extensible | Observation Interpretation Codes | 📦4.0.1 | FHIR Std. |
| Observation.component:diastolic.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:diastolic.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:diastolic.value[x].comparator | Base | required | QuantityComparator | 📍4.0.1 | FHIR Std. |
| Observation.component:diastolic.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:diastolic.interpretation | Base | extensible | Observation Interpretation Codes | 📦4.0.1 | FHIR Std. |
| Observation.component:va-cuff-size.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:va-cuff-size.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:va-cuff-size.value[x]:valueCodeableConcept | Base | required | VitalsCuffSize FHIR | 📦1.10.0 | This IG |
| Observation.component:va-cuff-size.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:va-cuff-size.interpretation | Base | extensible | Observation Interpretation Codes | 📦4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:va-pre-condition.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition.value[x]:valueCodeableConcept | Base | required | VitalsPrecondition FHIR | 📦1.10.0 | This IG |
| Observation.component:va-pre-condition.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition.interpretation | Base | extensible | Observation Interpretation Codes | 📦4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition-device.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:va-pre-condition-device.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition-device.value[x]:valueCodeableConcept | Base | required | VitalsQualifyingDevice FHIR | 📦1.10.0 | This IG |
| Observation.component:va-pre-condition-device.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition-device.interpretation | Base | extensible | Observation Interpretation Codes | 📦4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Observation | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
| obs-3 | error | Observation.referenceRange | Must have at least a low or a high or text |
low.exists() or high.exists() or text.exists()
|
| obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present |
dataAbsentReason.empty() or value.empty()
|
| obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present |
value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty()
|
| vs-1 | error | Observation.effective[x], Observation.effective[x]:effectiveDateTime | if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day |
($this as dateTime).toString().length() >= 8
|
| vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. |
(component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists())
|
| vs-3 | error | Observation.component, Observation.component:systolic, Observation.component:diastolic, Observation.component:va-cuff-size, Observation.component:va-pre-condition, Observation.component:va-pre-condition-device | If there is no a value a data absent reason must be present |
value.exists() or dataAbsentReason.exists()
|
| vsbp-12-655 | best practice | Observation.status | If (120.5-4) is null then fixed value #final |
true
|
| vsbp-12-656 | best practice | Observation.status | If (120.5-4) is not null then fixed value #entered-in-error |
true
|
| vsbp-12-664 | best practice | Observation.value[x]:valueQuantity.value | If VUID not = 4500634 then source value from (120.5-1.2) |
true
|
| vsbp-12-666 | best practice | Observation.component:systolic.value[x].value | If VUID = 4500634 then transform (120.5-1.2) using Split_rate_value.Systolic() |
true
|
| vsbp-12-667 | best practice | Observation.component:diastolic.value[x].value | If VUID = 4500634 then transform (120.5-1.2) using Split_rate_value.Diastolic() |
true
|
| vsbp-12-667-1 | best practice | Observation.component:diastolic.value[x].code | If VUID = 4500634 then fixed value #mm[Hg] |
true
|
| vsbp-12-666-1 | best practice | Observation.component:systolic.value[x].code | If VUID = 4500634 then fixed value #mm[Hg] |
true
|
| vsbp-12-666-2 | best practice | Observation.component:systolic.value[x].unit | If VUID = 4500634 then fixed value mm[Hg] |
true
|
| vsbp-12-667-2 | best practice | Observation.component:diastolic.value[x].unit | If VUID = 4500634 then fixed value mm[Hg] |
true
|
| vsbp-12-667-3 | best practice | Observation.component:diastolic.code | If VUID = 4500634 then fixed value http://loinc.org#8462-4 |
true
|
| vsbp-12-666-3 | best practice | Observation.component:systolic.code | If VUID = 4500634 then fixed value http://loinc.org#8480-6 |
true
|
This structure is derived from USCoreBloodPressureProfile
Summary
Must-Support: 20 elements
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Slices
This structure defines the following Slices:
Key Elements View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
C | 0..* | USCoreBloodPressureProfile(5.0.1) | US Core Blood Pressure Profile This profile also complies with the profiles US Core Blood Pressure Profile (6.1.0) and US Core Blood Pressure Profile (7.0.0) Constraints: obs-6, obs-7, vs-2 |
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
S | 0..1 | (Complex) | A code representing the the type of device used for this observation. Should only be used if not implicit in the code found in `Observation.code` URL: http://hl7.org/fhir/StructureDefinition/observation-deviceCode |
![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/StructureDefinition/observation-deviceCode" | |
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension Binding: VitalsMeasurementDevice FHIR (required): see mapping VF_VitalsMeasurementDevice |
![]() ![]() ![]() |
S | 0..1 | (Complex) | The body position during the observation URL: http://hl7.org/fhir/StructureDefinition/observation-bodyPosition |
![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/StructureDefinition/observation-bodyPosition" | |
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension Binding: VitalsBodyPosition FHIR (required): see mapping VF_VitalsBodyPosition |
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() |
Σ | 0..* | Identifier | Business Identifier for observation |
![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
![]() ![]() ![]() |
SΣ | 0..1 | uri | The namespace for the identifier value Required Pattern: http://va.gov/identifiers/{sta3n}/120.5 |
![]() ![]() ![]() |
SΣ | 0..1 | string | The value that is unique Example General: 123456 |
![]() ![]() |
?!SΣC | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required) Constraints: vsbp-12-655, vsbp-12-656 |
![]() ![]() |
S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following |
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |
![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() ![]() ![]() |
SΣ | 1..* | Coding | Code defined by a terminology system |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category |
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs |
![]() ![]() |
SΣ | 1..1 | CodeableConcept | Blood Pressure Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following |
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 85354-9 | |
![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |
![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() ![]() |
SΣ | 0..* | Coding | Code defined by a terminology system Binding: VitalsCodes FHIR (required): see mapping VF_VitalsCodes |
![]() ![]() |
SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about |
![]() ![]() |
SΣC | 1..1 | Often just a dateTime for Vital Signs Slice: Unordered, Open by type:$this Constraints: vs-1 | |
![]() ![]() ![]() |
dateTime S | |||
![]() ![]() ![]() |
Period | |||
![]() ![]() ![]() |
SΣC | 0..1 | dateTime S | Often just a dateTime for Vital Signs Constraints: vs-1 |
![]() ![]() |
SΣ | 0..1 | instant | Date/Time this version was made available |
![]() ![]() |
SΣ | 0..* | Reference(Organization) | Who is responsible for the observation |
![]() ![]() |
SΣC | 0..1 | Vital Signs Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |
![]() ![]() ![]() |
Quantity S | |||
![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() |
string | |||
![]() ![]() ![]() |
boolean | |||
![]() ![]() ![]() |
integer | |||
![]() ![]() ![]() |
Range | |||
![]() ![]() ![]() |
Ratio | |||
![]() ![]() ![]() |
SampledData | |||
![]() ![]() ![]() |
time | |||
![]() ![]() ![]() |
dateTime | |||
![]() ![]() ![]() |
Period | |||
![]() ![]() ![]() |
SΣC | 0..1 | Quantity S | Vital Signs Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-664 |
![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
![]() ![]() ![]() ![]() |
SΣ | 0..1 | code | Coded form of the unit |
![]() ![]() |
SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() |
S | 0..1 | CodeableConcept | Observed body part Binding: VitalsBodySite FHIR (required): see mapping VF_VitalsBodySite |
![]() ![]() |
S | 0..1 | CodeableConcept | How it was done Binding: VitalsMethod FHIR (required): see mapping VF_VitalsMethod |
![]() ![]() |
SΣC | 2..* | BackboneElement | Component observations Slice: Unordered, Open by pattern:code Constraints: vs-3 |
![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |
![]() ![]() ![]() ![]() ![]() |
Quantity S | |||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() ![]() ![]() |
string | |||
![]() ![]() ![]() ![]() ![]() |
boolean | |||
![]() ![]() ![]() ![]() ![]() |
integer | |||
![]() ![]() ![]() ![]() ![]() |
Range | |||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||
![]() ![]() ![]() ![]() ![]() |
time | |||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||
![]() ![]() ![]() ![]() ![]() |
Period | |||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() ![]() |
SΣC | 1..1 | BackboneElement | Systolic Blood Pressure Constraints: vs-3 |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣC | 1..1 | CodeableConcept | Systolic Blood Pressure Code Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Constraints: vsbp-12-666-3 Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 8480-6 | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-666 |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | string | Unit representation Constraints: vsbp-12-666-2 |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | code | Coded form of the unit Constraints: vsbp-12-666-1 Fixed Value: mm[Hg] |
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() ![]() |
SΣC | 1..1 | BackboneElement | Diastolic Blood Pressure Constraints: vs-3 |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣC | 1..1 | CodeableConcept | Diastolic Blood Pressure Code Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Constraints: vsbp-12-667-3 Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 8462-4 | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-667 |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | string | Unit representation Constraints: vsbp-12-667-2 |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | code | Coded form of the unit Constraints: vsbp-12-667-1 Fixed Value: mm[Hg] |
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() ![]() |
SΣC | 0..1 | BackboneElement | Component observations Constraints: vs-3 |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 8358-4 | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Blood pressure device cuff size | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Component Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |
![]() ![]() ![]() ![]() ![]() |
Quantity S | |||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() ![]() ![]() |
string | |||
![]() ![]() ![]() ![]() ![]() |
boolean | |||
![]() ![]() ![]() ![]() ![]() |
integer | |||
![]() ![]() ![]() ![]() ![]() |
Range | |||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||
![]() ![]() ![]() ![]() ![]() |
time | |||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||
![]() ![]() ![]() ![]() ![]() |
Period | |||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsCuffSize FHIR (required): see mapping VF_VitalsCuffSize |
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() ![]() |
SΣC | 0..1 | BackboneElement | Component observations Constraints: vs-3 |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 104158-1 | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Associated precondition - Reported | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Component Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |
![]() ![]() ![]() ![]() ![]() |
Quantity S | |||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() ![]() ![]() |
string | |||
![]() ![]() ![]() ![]() ![]() |
boolean | |||
![]() ![]() ![]() ![]() ![]() |
integer | |||
![]() ![]() ![]() ![]() ![]() |
Range | |||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||
![]() ![]() ![]() ![]() ![]() |
time | |||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||
![]() ![]() ![]() ![]() ![]() |
Period | |||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsPrecondition FHIR (required): see mapping VF_VitalsPrecondition |
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
![]() ![]() ![]() |
SΣC | 0..1 | BackboneElement | Component observations Constraints: vs-3 |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 104158-1 | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Associated precondition - Reported | |
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Component Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |
![]() ![]() ![]() ![]() ![]() |
Quantity S | |||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() ![]() ![]() |
string | |||
![]() ![]() ![]() ![]() ![]() |
boolean | |||
![]() ![]() ![]() ![]() ![]() |
integer | |||
![]() ![]() ![]() ![]() ![]() |
Range | |||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||
![]() ![]() ![]() ![]() ![]() |
time | |||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||
![]() ![]() ![]() ![]() ![]() |
Period | |||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsQualifyingDevice FHIR (required): see mapping VF_VitalsQualifyingDevice |
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
Documentation for this format | ||||
| Path | Status | Usage | ValueSet | Version | Source |
| Observation.extension:observation-deviceCode.value[x] | Base | required | VitalsMeasurementDevice FHIR | 📦1.10.0 | This IG |
| Observation.extension:observation-bodyPosition.value[x] | Base | required | VitalsBodyPosition FHIR | 📦1.10.0 | This IG |
| Observation.identifier.use | Base | required | IdentifierUse | 📍4.0.1 | FHIR Std. |
| Observation.status | Base | required | ObservationStatus | 📍4.0.1 | FHIR Std. |
| Observation.category | Base | preferred | Observation Category Codes | 📦4.0.1 | FHIR Std. |
| Observation.category:VSCat | Base | preferred | Observation Category Codes | 📦4.0.1 | FHIR Std. |
| Observation.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.code.coding | Base | required | VitalsCodes FHIR | 📦1.10.0 | This IG |
| Observation.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.value[x]:valueQuantity | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.value[x]:valueQuantity.comparator | Base | required | QuantityComparator | 📍4.0.1 | FHIR Std. |
| Observation.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.bodySite | Base | required | VitalsBodySite FHIR | 📦1.10.0 | This IG |
| Observation.method | Base | required | VitalsMethod FHIR | 📦1.10.0 | This IG |
| Observation.component.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:systolic.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:systolic.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:systolic.value[x].comparator | Base | required | QuantityComparator | 📍4.0.1 | FHIR Std. |
| Observation.component:systolic.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:diastolic.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:diastolic.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:diastolic.value[x].comparator | Base | required | QuantityComparator | 📍4.0.1 | FHIR Std. |
| Observation.component:diastolic.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:va-cuff-size.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:va-cuff-size.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:va-cuff-size.value[x]:valueCodeableConcept | Base | required | VitalsCuffSize FHIR | 📦1.10.0 | This IG |
| Observation.component:va-cuff-size.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:va-pre-condition.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition.value[x]:valueCodeableConcept | Base | required | VitalsPrecondition FHIR | 📦1.10.0 | This IG |
| Observation.component:va-pre-condition.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition-device.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:va-pre-condition-device.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition-device.value[x]:valueCodeableConcept | Base | required | VitalsQualifyingDevice FHIR | 📦1.10.0 | This IG |
| Observation.component:va-pre-condition-device.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Observation | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
| obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present |
dataAbsentReason.empty() or value.empty()
|
| obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present |
value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty()
|
| vs-1 | error | Observation.effective[x], Observation.effective[x]:effectiveDateTime | if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day |
($this as dateTime).toString().length() >= 8
|
| vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. |
(component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists())
|
| vs-3 | error | Observation.component, Observation.component:systolic, Observation.component:diastolic, Observation.component:va-cuff-size, Observation.component:va-pre-condition, Observation.component:va-pre-condition-device | If there is no a value a data absent reason must be present |
value.exists() or dataAbsentReason.exists()
|
| vsbp-12-655 | best practice | Observation.status | If (120.5-4) is null then fixed value #final |
true
|
| vsbp-12-656 | best practice | Observation.status | If (120.5-4) is not null then fixed value #entered-in-error |
true
|
| vsbp-12-664 | best practice | Observation.value[x]:valueQuantity.value | If VUID not = 4500634 then source value from (120.5-1.2) |
true
|
| vsbp-12-666 | best practice | Observation.component:systolic.value[x].value | If VUID = 4500634 then transform (120.5-1.2) using Split_rate_value.Systolic() |
true
|
| vsbp-12-667 | best practice | Observation.component:diastolic.value[x].value | If VUID = 4500634 then transform (120.5-1.2) using Split_rate_value.Diastolic() |
true
|
| vsbp-12-667-1 | best practice | Observation.component:diastolic.value[x].code | If VUID = 4500634 then fixed value #mm[Hg] |
true
|
| vsbp-12-666-1 | best practice | Observation.component:systolic.value[x].code | If VUID = 4500634 then fixed value #mm[Hg] |
true
|
| vsbp-12-666-2 | best practice | Observation.component:systolic.value[x].unit | If VUID = 4500634 then fixed value mm[Hg] |
true
|
| vsbp-12-667-2 | best practice | Observation.component:diastolic.value[x].unit | If VUID = 4500634 then fixed value mm[Hg] |
true
|
| vsbp-12-667-3 | best practice | Observation.component:diastolic.code | If VUID = 4500634 then fixed value http://loinc.org#8462-4 |
true
|
| vsbp-12-666-3 | best practice | Observation.component:systolic.code | If VUID = 4500634 then fixed value http://loinc.org#8480-6 |
true
|
Differential View
This structure is derived from USCoreBloodPressureProfile
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | USCoreBloodPressureProfile(5.0.1) | US Core Blood Pressure Profile This profile also complies with the profiles US Core Blood Pressure Profile (6.1.0) and US Core Blood Pressure Profile (7.0.0) | |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
S | 0..1 | (Complex) | A code representing the the type of device used for this observation. Should only be used if not implicit in the code found in `Observation.code` URL: http://hl7.org/fhir/StructureDefinition/observation-deviceCode |
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension Binding: VitalsMeasurementDevice FHIR (required): see mapping VF_VitalsMeasurementDevice |
![]() ![]() ![]() |
S | 0..1 | (Complex) | The body position during the observation URL: http://hl7.org/fhir/StructureDefinition/observation-bodyPosition |
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension Binding: VitalsBodyPosition FHIR (required): see mapping VF_VitalsBodyPosition |
![]() ![]() |
||||
![]() ![]() ![]() |
S | 0..1 | uri | The namespace for the identifier value Required Pattern: http://va.gov/identifiers/{sta3n}/120.5 |
![]() ![]() ![]() |
S | 0..1 | string | The value that is unique |
![]() ![]() |
C | 1..1 | code | registered | preliminary | final | amended + Constraints: vsbp-12-655, vsbp-12-656 |
![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() |
1..1 | CodeableConcept | Classification of type of observation Required Pattern: At least the following | |
![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | |
![]() ![]() |
||||
![]() ![]() ![]() |
S | 0..* | Coding | Code defined by a terminology system Binding: VitalsCodes FHIR (required): see mapping VF_VitalsCodes |
![]() ![]() |
1..1 | Reference(Patient) | Who and/or what the observation is about | |
![]() ![]() |
1..1 | dateTime, Period | Often just a dateTime for Vital Signs Slice: Unordered, Open by type:$this | |
![]() ![]() ![]() |
S | 0..1 | dateTime S | Often just a dateTime for Vital Signs |
![]() ![]() |
S | 0..1 | instant | Date/Time this version was made available |
![]() ![]() |
S | 0..* | Reference(Organization) | Who is responsible for the observation |
![]() ![]() |
0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Vital Signs Value Slice: Unordered, Open by type:$this | |
![]() ![]() ![]() |
0..1 | Quantity | Vital Signs Value | |
![]() ![]() ![]() ![]() |
SC | 0..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-664 |
![]() ![]() ![]() ![]() |
S | 0..1 | code | Coded form of the unit |
![]() ![]() |
S | 0..1 | CodeableConcept | Observed body part Binding: VitalsBodySite FHIR (required): see mapping VF_VitalsBodySite |
![]() ![]() |
S | 0..1 | CodeableConcept | How it was done Binding: VitalsMethod FHIR (required): see mapping VF_VitalsMethod |
![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() |
1..1 | BackboneElement | Systolic Blood Pressure | |
![]() ![]() ![]() ![]() |
C | 1..1 | CodeableConcept | Systolic Blood Pressure Code Constraints: vsbp-12-666-3 |
![]() ![]() ![]() ![]() |
||||
![]() ![]() ![]() ![]() ![]() |
C | 1..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-666 |
![]() ![]() ![]() ![]() ![]() |
C | 1..1 | string | Unit representation Constraints: vsbp-12-666-2 |
![]() ![]() ![]() ![]() ![]() |
C | 1..1 | code | Coded form of the unit Constraints: vsbp-12-666-1 |
![]() ![]() ![]() |
1..1 | BackboneElement | Diastolic Blood Pressure | |
![]() ![]() ![]() ![]() |
C | 1..1 | CodeableConcept | Diastolic Blood Pressure Code Constraints: vsbp-12-667-3 |
![]() ![]() ![]() ![]() |
||||
![]() ![]() ![]() ![]() ![]() |
C | 1..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-667 |
![]() ![]() ![]() ![]() ![]() |
C | 1..1 | string | Unit representation Constraints: vsbp-12-667-2 |
![]() ![]() ![]() ![]() ![]() |
C | 1..1 | code | Coded form of the unit Constraints: vsbp-12-667-1 |
![]() ![]() ![]() |
S | 0..1 | BackboneElement | Component observations |
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Type of component observation (code / type) Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 8358-4 | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Blood pressure device cuff size | |
![]() ![]() ![]() ![]() |
0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Vital Sign Component Value Slice: Unordered, Open by type:$this | |
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsCuffSize FHIR (required): see mapping VF_VitalsCuffSize |
![]() ![]() ![]() |
S | 0..1 | BackboneElement | Component observations |
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Type of component observation (code / type) Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 104158-1 | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Associated precondition - Reported | |
![]() ![]() ![]() ![]() |
0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Vital Sign Component Value Slice: Unordered, Open by type:$this | |
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsPrecondition FHIR (required): see mapping VF_VitalsPrecondition |
![]() ![]() ![]() |
S | 0..1 | BackboneElement | Component observations |
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Type of component observation (code / type) Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 104158-1 | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Associated precondition - Reported | |
![]() ![]() ![]() ![]() |
0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Vital Sign Component Value Slice: Unordered, Open by type:$this | |
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsQualifyingDevice FHIR (required): see mapping VF_VitalsQualifyingDevice |
Documentation for this format | ||||
| Path | Status | Usage | ValueSet | Version | Source |
| Observation.extension:observation-deviceCode.value[x] | Base | required | VitalsMeasurementDevice FHIR | 📦1.10.0 | This IG |
| Observation.extension:observation-bodyPosition.value[x] | Base | required | VitalsBodyPosition FHIR | 📦1.10.0 | This IG |
| Observation.code.coding | Base | required | VitalsCodes FHIR | 📦1.10.0 | This IG |
| Observation.bodySite | Base | required | VitalsBodySite FHIR | 📦1.10.0 | This IG |
| Observation.method | Base | required | VitalsMethod FHIR | 📦1.10.0 | This IG |
| Observation.component:va-cuff-size.value[x]:valueCodeableConcept | Base | required | VitalsCuffSize FHIR | 📦1.10.0 | This IG |
| Observation.component:va-pre-condition.value[x]:valueCodeableConcept | Base | required | VitalsPrecondition FHIR | 📦1.10.0 | This IG |
| Observation.component:va-pre-condition-device.value[x]:valueCodeableConcept | Base | required | VitalsQualifyingDevice FHIR | 📦1.10.0 | This IG |
| Id | Grade | Path(s) | Description | Expression |
| vsbp-12-655 | best practice | Observation.status | If (120.5-4) is null then fixed value #final |
true
|
| vsbp-12-656 | best practice | Observation.status | If (120.5-4) is not null then fixed value #entered-in-error |
true
|
| vsbp-12-664 | best practice | Observation.value[x]:valueQuantity.value | If VUID not = 4500634 then source value from (120.5-1.2) |
true
|
| vsbp-12-666 | best practice | Observation.component:systolic.value[x].value | If VUID = 4500634 then transform (120.5-1.2) using Split_rate_value.Systolic() |
true
|
| vsbp-12-667 | best practice | Observation.component:diastolic.value[x].value | If VUID = 4500634 then transform (120.5-1.2) using Split_rate_value.Diastolic() |
true
|
| vsbp-12-667-1 | best practice | Observation.component:diastolic.value[x].code | If VUID = 4500634 then fixed value #mm[Hg] |
true
|
| vsbp-12-666-1 | best practice | Observation.component:systolic.value[x].code | If VUID = 4500634 then fixed value #mm[Hg] |
true
|
| vsbp-12-666-2 | best practice | Observation.component:systolic.value[x].unit | If VUID = 4500634 then fixed value mm[Hg] |
true
|
| vsbp-12-667-2 | best practice | Observation.component:diastolic.value[x].unit | If VUID = 4500634 then fixed value mm[Hg] |
true
|
| vsbp-12-667-3 | best practice | Observation.component:diastolic.code | If VUID = 4500634 then fixed value http://loinc.org#8462-4 |
true
|
| vsbp-12-666-3 | best practice | Observation.component:systolic.code | If VUID = 4500634 then fixed value http://loinc.org#8480-6 |
true
|
Snapshot View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||
|---|---|---|---|---|---|---|---|---|
![]() |
C | 0..* | USCoreBloodPressureProfile(5.0.1) | US Core Blood Pressure Profile This profile also complies with the profiles US Core Blood Pressure Profile (6.1.0) and US Core Blood Pressure Profile (7.0.0) Constraints: obs-6, obs-7, vs-2 | ||||
![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
S | 0..1 | (Complex) | A code representing the the type of device used for this observation. Should only be used if not implicit in the code found in `Observation.code` URL: http://hl7.org/fhir/StructureDefinition/observation-deviceCode | ||||
![]() ![]() ![]() ![]() |
0..1 | id | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||||||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/StructureDefinition/observation-deviceCode" | |||||
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension Binding: VitalsMeasurementDevice FHIR (required): see mapping VF_VitalsMeasurementDevice | ||||
![]() ![]() ![]() |
S | 0..1 | (Complex) | The body position during the observation URL: http://hl7.org/fhir/StructureDefinition/observation-bodyPosition | ||||
![]() ![]() ![]() ![]() |
0..1 | id | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..0 | Extension Slice: Unordered, Open by value:url | ||||||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/StructureDefinition/observation-bodyPosition" | |||||
![]() ![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Value of extension Binding: VitalsBodyPosition FHIR (required): see mapping VF_VitalsBodyPosition | ||||
![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() |
Σ | 0..* | Identifier | Business Identifier for observation | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() |
Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
![]() ![]() ![]() |
SΣ | 0..1 | uri | The namespace for the identifier value Required Pattern: http://va.gov/identifiers/{sta3n}/120.5 | ||||
![]() ![]() ![]() |
SΣ | 0..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() |
Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
![]() ![]() |
Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
![]() ![]() |
?!SΣC | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required) Constraints: vsbp-12-655, vsbp-12-656 | ||||
![]() ![]() |
S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
SΣ | 1..* | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Version of the system - if relevant | ||||
![]() ![]() ![]() ![]() ![]() |
SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Representation defined by the system | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
SΣ | 1..1 | CodeableConcept | Blood Pressure Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 85354-9 | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |||||
![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() |
SΣ | 0..* | Coding | Code defined by a terminology system Binding: VitalsCodes FHIR (required): see mapping VF_VitalsCodes | ||||
![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about | ||||
![]() ![]() |
Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
![]() ![]() |
Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
![]() ![]() |
SΣC | 1..1 | Often just a dateTime for Vital Signs Slice: Unordered, Open by type:$this Constraints: vs-1 | |||||
![]() ![]() ![]() |
dateTime S | |||||||
![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() |
SΣC | 0..1 | dateTime S | Often just a dateTime for Vital Signs Constraints: vs-1 | ||||
![]() ![]() |
SΣ | 0..1 | instant | Date/Time this version was made available | ||||
![]() ![]() |
SΣ | 0..* | Reference(Organization) | Who is responsible for the observation | ||||
![]() ![]() |
SΣC | 0..1 | Vital Signs Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |||||
![]() ![]() ![]() |
Quantity S | |||||||
![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() |
boolean | |||||||
![]() ![]() ![]() |
integer | |||||||
![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() |
Ratio | |||||||
![]() ![]() ![]() |
SampledData | |||||||
![]() ![]() ![]() |
time | |||||||
![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() |
SΣC | 0..1 | Quantity S | Vital Signs Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-664 | ||||
![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Unit representation | ||||
![]() ![]() ![]() ![]() |
ΣC | 0..1 | uri | System that defines coded unit form | ||||
![]() ![]() ![]() ![]() |
SΣ | 0..1 | code | Coded form of the unit | ||||
![]() ![]() |
SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() |
0..* | Annotation | Comments about the observation | |||||
![]() ![]() |
S | 0..1 | CodeableConcept | Observed body part Binding: VitalsBodySite FHIR (required): see mapping VF_VitalsBodySite | ||||
![]() ![]() |
S | 0..1 | CodeableConcept | How it was done Binding: VitalsMethod FHIR (required): see mapping VF_VitalsMethod | ||||
![]() ![]() |
0..1 | Reference(Specimen) | Specimen used for this observation | |||||
![]() ![]() |
0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||
![]() ![]() |
C | 0..* | BackboneElement | Provides guide for interpretation Constraints: obs-3 | ||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() |
C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
![]() ![]() ![]() |
C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
![]() ![]() ![]() |
0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
![]() ![]() ![]() |
0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
![]() ![]() ![]() |
0..1 | Range | Applicable age range, if relevant | |||||
![]() ![]() ![]() |
0..1 | string | Text based reference range in an observation | |||||
![]() ![]() |
Σ | 0..* | Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Used when reporting vital signs panel components | ||||
![]() ![]() |
Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Related measurements the observation is made from | ||||
![]() ![]() |
SΣC | 2..* | BackboneElement | Component observations Slice: Unordered, Open by pattern:code Constraints: vs-3 | ||||
![]() ![]() ![]() |
Content/Rules for all slices | |||||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. | ||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |||||
![]() ![]() ![]() ![]() ![]() |
Quantity S | |||||||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() ![]() ![]() |
boolean | |||||||
![]() ![]() ![]() ![]() ![]() |
integer | |||||||
![]() ![]() ![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||||||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||||||
![]() ![]() ![]() ![]() ![]() |
time | |||||||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
![]() ![]() ![]() |
SΣC | 1..1 | BackboneElement | Systolic Blood Pressure Constraints: vs-3 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣC | 1..1 | CodeableConcept | Systolic Blood Pressure Code Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Constraints: vsbp-12-666-3 Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 8480-6 | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-666 | ||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | string | Unit representation Constraints: vsbp-12-666-2 | ||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | code | Coded form of the unit Constraints: vsbp-12-666-1 Fixed Value: mm[Hg] | ||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
![]() ![]() ![]() |
SΣC | 1..1 | BackboneElement | Diastolic Blood Pressure Constraints: vs-3 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣC | 1..1 | CodeableConcept | Diastolic Blood Pressure Code Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Constraints: vsbp-12-667-3 Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 8462-4 | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Representation defined by the system | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Quantity | Vital Sign Component Value Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | decimal | Numerical value (with implicit precision) Constraints: vsbp-12-667 | ||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | string | Unit representation Constraints: vsbp-12-667-2 | ||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 1..1 | code | Coded form of the unit Constraints: vsbp-12-667-1 Fixed Value: mm[Hg] | ||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
![]() ![]() ![]() |
SΣC | 0..1 | BackboneElement | Component observations Constraints: vs-3 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 8358-4 | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Blood pressure device cuff size | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Component Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |||||
![]() ![]() ![]() ![]() ![]() |
Quantity S | |||||||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() ![]() ![]() |
boolean | |||||||
![]() ![]() ![]() ![]() ![]() |
integer | |||||||
![]() ![]() ![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||||||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||||||
![]() ![]() ![]() ![]() ![]() |
time | |||||||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsCuffSize FHIR (required): see mapping VF_VitalsCuffSize | ||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
![]() ![]() ![]() |
SΣC | 0..1 | BackboneElement | Component observations Constraints: vs-3 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 104158-1 | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Associated precondition - Reported | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Component Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |||||
![]() ![]() ![]() ![]() ![]() |
Quantity S | |||||||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() ![]() ![]() |
boolean | |||||||
![]() ![]() ![]() ![]() ![]() |
integer | |||||||
![]() ![]() ![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||||||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||||||
![]() ![]() ![]() ![]() ![]() |
time | |||||||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsPrecondition FHIR (required): see mapping VF_VitalsPrecondition | ||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
![]() ![]() ![]() |
SΣC | 0..1 | BackboneElement | Component observations Constraints: vs-3 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (Complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: 104158-1 | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Associated precondition - Reported | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() |
SΣC | 0..1 | Vital Sign Component Value Slice: Unordered, Open by type:$this Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |||||
![]() ![]() ![]() ![]() ![]() |
Quantity S | |||||||
![]() ![]() ![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() ![]() ![]() |
string | |||||||
![]() ![]() ![]() ![]() ![]() |
boolean | |||||||
![]() ![]() ![]() ![]() ![]() |
integer | |||||||
![]() ![]() ![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() ![]() ![]() |
Ratio | |||||||
![]() ![]() ![]() ![]() ![]() |
SampledData | |||||||
![]() ![]() ![]() ![]() ![]() |
time | |||||||
![]() ![]() ![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() ![]() ![]() |
SΣC | 0..1 | CodeableConcept | Vital Sign Component Value Binding: VitalsQualifyingDevice FHIR (required): see mapping VF_VitalsQualifyingDevice | ||||
![]() ![]() ![]() ![]() |
SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
![]() ![]() ![]() ![]() |
0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format | ||||||||
| Path | Status | Usage | ValueSet | Version | Source |
| Observation.language | Base | preferred | Common Languages | 📦4.0.1 | FHIR Std. |
| Observation.extension:observation-deviceCode.value[x] | Base | required | VitalsMeasurementDevice FHIR | 📦1.10.0 | This IG |
| Observation.extension:observation-bodyPosition.value[x] | Base | required | VitalsBodyPosition FHIR | 📦1.10.0 | This IG |
| Observation.identifier.use | Base | required | IdentifierUse | 📍4.0.1 | FHIR Std. |
| Observation.identifier.type | Base | extensible | IdentifierType | 📍4.0.1 | FHIR Std. |
| Observation.status | Base | required | ObservationStatus | 📍4.0.1 | FHIR Std. |
| Observation.category | Base | preferred | Observation Category Codes | 📦4.0.1 | FHIR Std. |
| Observation.category:VSCat | Base | preferred | Observation Category Codes | 📦4.0.1 | FHIR Std. |
| Observation.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.code.coding | Base | required | VitalsCodes FHIR | 📦1.10.0 | This IG |
| Observation.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.value[x]:valueQuantity | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.value[x]:valueQuantity.comparator | Base | required | QuantityComparator | 📍4.0.1 | FHIR Std. |
| Observation.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.interpretation | Base | extensible | Observation Interpretation Codes | 📦4.0.1 | FHIR Std. |
| Observation.bodySite | Base | required | VitalsBodySite FHIR | 📦1.10.0 | This IG |
| Observation.method | Base | required | VitalsMethod FHIR | 📦1.10.0 | This IG |
| Observation.referenceRange.type | Base | preferred | Observation Reference Range Meaning Codes | 📦4.0.1 | FHIR Std. |
| Observation.referenceRange.appliesTo | Base | example | Observation Reference Range Applies To Codes | 📦4.0.1 | FHIR Std. |
| Observation.component.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component.interpretation | Base | extensible | Observation Interpretation Codes | 📦4.0.1 | FHIR Std. |
| Observation.component:systolic.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:systolic.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:systolic.value[x].comparator | Base | required | QuantityComparator | 📍4.0.1 | FHIR Std. |
| Observation.component:systolic.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:systolic.interpretation | Base | extensible | Observation Interpretation Codes | 📦4.0.1 | FHIR Std. |
| Observation.component:diastolic.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:diastolic.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:diastolic.value[x].comparator | Base | required | QuantityComparator | 📍4.0.1 | FHIR Std. |
| Observation.component:diastolic.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:diastolic.interpretation | Base | extensible | Observation Interpretation Codes | 📦4.0.1 | FHIR Std. |
| Observation.component:va-cuff-size.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:va-cuff-size.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:va-cuff-size.value[x]:valueCodeableConcept | Base | required | VitalsCuffSize FHIR | 📦1.10.0 | This IG |
| Observation.component:va-cuff-size.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:va-cuff-size.interpretation | Base | extensible | Observation Interpretation Codes | 📦4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:va-pre-condition.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition.value[x]:valueCodeableConcept | Base | required | VitalsPrecondition FHIR | 📦1.10.0 | This IG |
| Observation.component:va-pre-condition.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition.interpretation | Base | extensible | Observation Interpretation Codes | 📦4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition-device.code | Base | extensible | US Core Vital Signs ValueSet | 📦6.1.0 | US Core v6.1 |
| Observation.component:va-pre-condition-device.value[x] | Base | extensible | Vital Signs Units | 📍4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition-device.value[x]:valueCodeableConcept | Base | required | VitalsQualifyingDevice FHIR | 📦1.10.0 | This IG |
| Observation.component:va-pre-condition-device.dataAbsentReason | Base | extensible | DataAbsentReason | 📦4.0.1 | FHIR Std. |
| Observation.component:va-pre-condition-device.interpretation | Base | extensible | Observation Interpretation Codes | 📦4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Observation | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
| obs-3 | error | Observation.referenceRange | Must have at least a low or a high or text |
low.exists() or high.exists() or text.exists()
|
| obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present |
dataAbsentReason.empty() or value.empty()
|
| obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present |
value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty()
|
| vs-1 | error | Observation.effective[x], Observation.effective[x]:effectiveDateTime | if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day |
($this as dateTime).toString().length() >= 8
|
| vs-2 | error | Observation | If there is no component or hasMember element then either a value[x] or a data absent reason must be present. |
(component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists())
|
| vs-3 | error | Observation.component, Observation.component:systolic, Observation.component:diastolic, Observation.component:va-cuff-size, Observation.component:va-pre-condition, Observation.component:va-pre-condition-device | If there is no a value a data absent reason must be present |
value.exists() or dataAbsentReason.exists()
|
| vsbp-12-655 | best practice | Observation.status | If (120.5-4) is null then fixed value #final |
true
|
| vsbp-12-656 | best practice | Observation.status | If (120.5-4) is not null then fixed value #entered-in-error |
true
|
| vsbp-12-664 | best practice | Observation.value[x]:valueQuantity.value | If VUID not = 4500634 then source value from (120.5-1.2) |
true
|
| vsbp-12-666 | best practice | Observation.component:systolic.value[x].value | If VUID = 4500634 then transform (120.5-1.2) using Split_rate_value.Systolic() |
true
|
| vsbp-12-667 | best practice | Observation.component:diastolic.value[x].value | If VUID = 4500634 then transform (120.5-1.2) using Split_rate_value.Diastolic() |
true
|
| vsbp-12-667-1 | best practice | Observation.component:diastolic.value[x].code | If VUID = 4500634 then fixed value #mm[Hg] |
true
|
| vsbp-12-666-1 | best practice | Observation.component:systolic.value[x].code | If VUID = 4500634 then fixed value #mm[Hg] |
true
|
| vsbp-12-666-2 | best practice | Observation.component:systolic.value[x].unit | If VUID = 4500634 then fixed value mm[Hg] |
true
|
| vsbp-12-667-2 | best practice | Observation.component:diastolic.value[x].unit | If VUID = 4500634 then fixed value mm[Hg] |
true
|
| vsbp-12-667-3 | best practice | Observation.component:diastolic.code | If VUID = 4500634 then fixed value http://loinc.org#8462-4 |
true
|
| vsbp-12-666-3 | best practice | Observation.component:systolic.code | If VUID = 4500634 then fixed value http://loinc.org#8480-6 |
true
|
This structure is derived from USCoreBloodPressureProfile
Summary
Must-Support: 20 elements
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Slices
This structure defines the following Slices:
Other representations of profile: CSV, Excel, Schematron